Product
- Home
- Product




Trans-MiniAMF
Trans-MiniAMFAutomatic Genset Controller with Transfer Switching
CanBus J1939 ECU communication
Remote Start/Stop, Speed and Idle mode control via J1939
Power factor measurement for 1 phases
Selectable Resistive sender types; Pt-100, VDO, US, GM, Ford, Datcon, etc…
Speed sensing from alternator voltage or magnetic pickup
SPN, FMI and OC values reading from engines via J1939
Contact our team for technical specifications.
Trans-MiniAMF User Manuals
Automatic Mains Failure Unit Trans-MiniAMF_Manual_EN_V17
Related products
Related Product
Trans-I/O
Trans-I/OExpansion Inputs/Outputs module
Easy plugging to all Trans series controllers, Configurable 8 inputs and 8 outputs, Each input and output configurable by user or select from list, Selectable hardware type of inputs by +Ve or -Ve, Selectable NO or NC input polarity, Selectable NO or NC output polarity, Adjustable input active delay, Can be used together with remote monitoring modules
Trans-AUTO
Trans-AUTOAutomatic Genset Controller
Canbus J1939 ECU communication
Selectable second language
Generator phase sequence control
Power factor measurement for 3 phases
Selectable Resistive sender types; Pt-100, VDO, US, GM, Ford, Datcon, etc..
SPN, FMI and OC values reading from engines via J1939
Active, Reactive, Apparent power measurement
Gencharger
Battery Charger
Float charging, 67 KHz switching, Constant output voltage Current limiting, Fail (Relay) output, High Current and short circuit protection, Reverse connection protection, High temperature protection, Wide range operation voltage, Suitable for Lead Acid battery
ESM-3712-HCN
ESM-3712-HCNDigital ON / OFF Temperature Controller(ALARM+SET)
Installing parameters using Prokey
2 Output for compressor and alarm controls
Process Set value and Alarm Set value low limit and
set value high limit boundaries
4 Digits Display
NTC Inputor PTC Input (Must be determined in order)
ON/OFF temperature control
Selectable heating or cooling function
Selection of operation with hysteresis
Adjustable temperature offset
Alarm parameters
Adjustable internal buzzer according to Sensor
prob defect and Alarm status
Remote access, data collecting and controlling
with Modbus RTU (Optional)
Trans-KEY
Trans-KEY Manual and Remote Start Unit with Key Switch
Engine start and stop Automatic shutdown on fault condition Provides alarm and status information Alarm and shutdown inputs Provides charge alternator excitation current Lamp test function
Trans-CRANK
Trans-CRANK Manuel Start Unit with Key Switch
Designed for generator,Pump & Fire Pump Applications Engine start/stop,Automatic shutdown on fault condition,Provides alarm and status information,Alarm and shutdown inputs,Provides charge alternator excitation currrent,Lamp test function